- 267-263-2308
- info@uspunderlayment.com
RoofTopGuard SA Technical Data
RoofTopGuard SA Technical Data
|
ICC-ES AC48 |
|||||||
|
PROPERTY |
STANDARD |
RESULTS - ROOFTOPGUARD SA |
UNITS |
||||
|
Tensile Strength |
D2523 per D1970 |
|
MD |
XMD |
|||
|
control |
|
94 |
71 |
lbf/in |
|||
|
accelerated aged |
|
31 |
32 |
lbf/in |
|||
|
UV exposed |
|
34 |
33 |
lbf/in |
|||
|
Water Vapor Permeance |
E96(A) |
|
|
0 |
perms |
||
|
Pliability |
AC48 |
|
PASS |
no crack |
|||
|
Water ponding |
AC48 |
|
|
||||
|
control |
|
PASS |
no leak |
||||
|
accelerated aged |
|
|
PASS |
no leak |
|||
|
Cycling and elongation |
AC48 |
|
|
PASS |
no crack or delamination |
||
|
Accelerated Aging |
AC48 |
|
PASS |
no damage |
|||
|
UV Exposure |
AC48 |
|
|
PASS |
no damage |
||
|
ASTM D1970 |
|||||||
|
PROPERTY |
STANDARD |
RESULTS - ROOFTOPGUARD SA |
UNITS |
||||
|
Low Temp Unrolling |
D1970 |
|
PASS |
no crack |
|||
|
High Temp Unrolling |
D1970 |
PASS |
no crack |
||||
|
Thickness |
D5147 |
|
26 |
mils |
|||
|
Load-Strain |
D2523 |
MD |
XMD |
||||
|
94 |
71 |
lbf/in |
|||||
|
33 |
47 |
% |
|||||
|
Adhesion to Plywood at 40°F |
D903 |
|
95 |
lbf/ft |
|||
|
Adhesion to Plywood at 75°F |
D903 |
35 |
lbf/ft |
||||
|
Thermal Stability |
D1970 |
0 |
inch |
||||
|
Flexibility Temperature |
D1970 |
|
PASS |
no crack |
|||
|
Tear Resistance |
D4073 |
MD |
XMD |
||||
|
139 |
128 |
lbf |
|||||
|
Moisture Vapor Permeability |
E96 |
|
0 |
perms |
|||
|
Sealability Around Nail |
D1970 |
PASS |
no leak |
||||
|
Waterproof Integrity after low temp flex |
D1970 |
PASS |
no leak |
||||
|
Waterproof Integrity of Seam |
D1970 |
PASS |
no leak |
||||
|
Slip Resistance |
D1970 |
|
1.31 > 0.86 |
> felt |
|||
|
ACCELERATED WEATHERING FOR 180 DAY EXPOSURE |
|||||||
|
PROPERTY |
STANDARD |
RESULTS - ROOFTOPGUARD SA |
UNITS |
||||
|
Accelerated Weathering |
D4798, 1000 hrs |
|
PASS |
no damage |
|||
|
Load-Strain, post-AW |
D2523 |
MD |
XMD |
||||
|
92 |
76 |
lbf/in |
|||||
|
Adhesion to Plywood at 40F, post-AW |
D903 |
|
61 |
lbf/ft |
|||
|
Adhesion to Plywood at 75F, post-AW |
D903 |
57 |
lbf/ft |
||||
|
Low Temp Flex, post-AW |
D1970 |
|
PASS |
no crack |
|||
|
Tear Resistance, post-AW |
D4073 |
MD |
XMD |
||||
|
135 |
128 |
lbf |
|||||
|
Tear Resistance, post-AW |
D1938 per TAS 103 |
MD |
XMD |
||||
|
12.3 |
11.9 |
lbf |
|||||
|
Water Vapor Transmission, post-AW |
E96 |
|
0.33 |
g/m2-24 hrs |
|||
|
Crack Cycling, post-AW |
AC48 per TAS 103 |
|
PASS |
no crack or delamination |
|||
|
FRSA / TRI INSTALLATION MANUAL |
|||||||
|
PROPERTY |
STANDARD |
RESULTS - ROOFTOPGUARD SA |
PROPERTY |
||||
|
Wind Uplift |
TAS 124 per TAS 103 |
|
PASS |
PASS 90 PSF |
|||
|
Tear Resistance |
D1938 per TAS 103 |
MD |
XMD |
||||
|
10.9 |
10.2 |
lbf |
|||||
|
Load-Strain, control |
D2523 per TAS 103 |
MD |
XMD |
||||
|
95 |
72 |
lbf/in |
|||||
|
33 |
47 |
% |
|||||
|
Water Vapor Transmission |
E96(B) per TAS 103 |
|
0.38 |
g/m2-24 hrs |
|||
|
Tile Slippage Resistance |
TAS 103 |
PASS |
no slip or damage |
||||
|
Crack Cycling |
AC48 per TAS 103 |
|
PASS |
no crack |
|||
|
Sealability Around Nail |
D1970 |
PASS |
no leak |
||||
|
Cycling and elongation |
AC48 |
PASS |
no crack |
||||